Non-Compliance detail


  
Summary
 
Licence number: 573
Annual Return Start: 01 Nov 2012
Annual Return End: 31 Oct 2013
Date Received: 30 Dec 2013
 
Licence Condition numberType of non-complianceEPA actionsNo. of times occurred
M6 The flow was not monitored for five days during planned shutdown due to planned maintenance. EPA was advised in advance Appropriate Action taken by licensee 1
L3 Total Phosphorus was exceeded due to a clarifier failure. The 100% limit was exceeded on two occasions. These incidents were caused by a clarifier failure. More effective lubrication has been installed on both clarifier to prevent a recurrence. Appropriate Action taken by licensee 2
L3 Faecal coliform 90% limit and 100% limit were exceeded a number of times due to a chlorine dosing failure. Appropriate Action taken by licensee 6
L3 BOD and TSS 100% limits were exceeded once each due to an unexpected algal growth during warm weather. Minor algal growths cause multiple 90% limit TSS exceedences. Appropriate Action taken by licensee 13