Non-Compliance detail


  
Summary
 
Licence number: 4022
Annual Return Start: 13 May 2014
Annual Return End: 31 Dec 2014
Date Received: 27 Feb 2015
 
Licence Condition numberType of non-complianceEPA actionsNo. of times occurred
Sch. 4 Cond. 18 Non-accidental falling of trees toward filter strip due to operator error. Operator instructed to apply correct direction falling techniques and falling away from marked exclusion zone/boundary. EPA to monitor future compliance with this condition 1
Sch. 5 Cond. 11 Constructed drainage controls on internal compartment road not up to EPL standard due to operator error; failure to identify non-compliant crossbanks and apply corrective measures. Staff required to complete training courses. EPA to monitor future compliance with this condition 1
Sch 5. Cond. 70 Snig track drainage controls did not meet EPL standard due to operator error; failure to measure correct slope of snig track and subsequent failure to implement correct drainage control. Staff required to complete training courses. EPA to monitor future compliance with this condition 1
Sch. 4 Cond. 20 Mechanical harvesting operator failed to identify location of taped line obscured by vegetation and walked falling machine into a first order filter strip exclusion zone. No adverse effects. Operator stopped and backed out. No trees cut. EPA to monitor future compliance with this condition 1